EPS/BT 20000 Triple Regenerative Battery Tester 4 - 30 kW
EPS/BT 20010-400 Triple Regenerative Battery Tester
Order code: 700040
Voltage: 0-10 VDC / 0-10 VDC / 0-10 VDC
Current: +- 400 A / +-400 A / +-400 A
Power: 12000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-10 VDC / 0-10 VDC / 0-10 VDC
Current: +- 400 A / +-400 A / +-400 A
Power: 12000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 10 V DC
In-/Output Current: +-0 A - 400 A/channel
Output Power:+-12000 W (4000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,1%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 10 V DC
In-/Output Current: +-0 A - 400 A/channel
Output Power:+-12000 W (4000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,1%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20010-600 Triple Regenerative Battery Tester
Order code: 700041
Voltage: 0-10 VDC / 0-10 VDC / 0-10 VDC
Current: +- 600 A / +-600 A / +-600 A
Power: 18000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-10 VDC / 0-10 VDC / 0-10 VDC
Current: +- 600 A / +-600 A / +-600 A
Power: 18000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 10 V DC
In-/Output Current: +-0 A - 600 A/channel
Output Power:+-18000 W (6000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,1%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 10 V DC
In-/Output Current: +-0 A - 600 A/channel
Output Power:+-18000 W (6000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,1%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20060-340 Triple Regenerative Battery Tester
Order code: 700042
Voltage: 0-60 VDC / 0-60 VDC / 0-60 VDC
Current: 0-340 A / +-340 A / +-340 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-60 VDC / 0-60 VDC / 0-60 VDC
Current: 0-340 A / +-340 A / +-340 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 60 V DC
In-/Output Current: +-0 A - 340 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,1%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 60 V DC
In-/Output Current: +-0 A - 340 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,1%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20080-340 Triple Regenerative Battery Tester
Order code: 700043
Voltage: 0-80 VDC / 0-80 VDC / 0-80 VDC
Current: 0-340 A / +-340 A / +-340 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-80 VDC / 0-80 VDC / 0-80 VDC
Current: 0-340 A / +-340 A / +-340 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 80 V DC
In-/Output Current: +-0 A - 340 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 80 V DC
In-/Output Current: +-0 A - 340 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20010-140 Triple Regenerative Battery Tester
Order code: 700044
Voltage: 0-200 VDC / 0-200 VDC / 0-200 VDC
Current: 0-140 A / +-140 A / +-140 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-200 VDC / 0-200 VDC / 0-200 VDC
Current: 0-140 A / +-140 A / +-140 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 10 V DC
In-/Output Current: +-0 A - 140 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,3%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 10 V DC
In-/Output Current: +-0 A - 140 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,3%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20360-80 Triple Regenerative Battery Tester
Order code: 700045
Voltage: 0-360 VDC / 0-360 VDC / 0-360 VDC
Current: 0-80 A / +-80 A / +-80 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-360 VDC / 0-360 VDC / 0-360 VDC
Current: 0-80 A / +-80 A / +-80 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 360 V DC
In-/Output Current: +-0 A - 80 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,8%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 360 V DC
In-/Output Current: +-0 A - 80 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,8%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20500-60 Triple Regenerative Battery Tester
Order code: 700046
Voltage: 0-500 VDC / 0-500 VDC / 0-500 VDC
Current: 0-60 A / +-60 A / +-60 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-500 VDC / 0-500 VDC / 0-500 VDC
Current: 0-60 A / +-60 A / +-60 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 500 V DC
In-/Output Current: +-0 A - 60 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 500 V DC
In-/Output Current: +-0 A - 60 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
EPS/BT 20920-40 Triple Regenerative Battery Tester
Order code: 700047
Voltage: 0-920 VDC / 0-920 VDC / 0-920 VDC
Current: 0-40 A / +-40 A / +-40 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Voltage: 0-920 VDC / 0-920 VDC / 0-920 VDC
Current: 0-40 A / +-40 A / +-40 A
Power: 0-30000 W
Design: 19 inch
Operating Characteristic: Bidirectional
Shipping time:
3 Channels
Output Voltage: 0 V DC - 920 V DC
In-/Output Current: +-0 A - 40 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Voltage: 0 V DC - 920 V DC
In-/Output Current: +-0 A - 40 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs
Country of origin: Germany
Customs tariff code: 8504.3200