EPS/TSDCR Regenerative bidirectional Testsystems 60kW-1,3 MW Source - Sink - Battery Charger/Tester/Simulator - Inverter - up to 1300kW/kVA from EPS Stromversorgung

The coordinated test systems EPS/TSDCR from EPS Electronic Power Supplies are for tests accompanying development, such as simulation of the on-board grid, simulation of energy storage devices (e.g. LiIon battery simulation), tests of electrical drives as well as fuel cells and their corresponding components such as inverters, batteries (charging and discharging) and switch suitable. The outputs go up to 650kW in a voltage range from 5 to 1000V and a current range up to 1000A.

The special feature of these systems is that the electrical energy consumed in generator mode is fed back into the grid with high efficiency. External loads (resistors) are thus superfluous and electrical energy that is otherwise "burned" can be returned profitably. This feedback capability is a decisive factor in most test applications, as unusually high outputs are used here. Either parallel connection (up to 2000A) or a multi-channel system (up to 4000A) is possible to increase performance. In contrast to conventional DC sources, the multi-channel system has two or four independently usable output channels and can work both as a source and as a sink.

All systems have an isolated output and a TFT touch panel for entering or displaying values and alarms.

They can also be controlled via CAN, MOD-Bus, SCPI / TCP-IP, VNC and optionally via RS232 / USB, HighSpeed /Analog, HighSpeed CAN, Profibus, Profinet and Ethercat.

The test system can be freely programmed and has specific algorithms that enable a wide variety of tests such as testing solar systems (inverter option), super capacitors and reactive power compensation.

Comprehensive protective measures, such as an event memory integrated as standard and a safety control (level "d") round off the concept.

The system can be "upgraded" customer-specifically, e.g. with insulation monitoring, an additional discharge unit in the event of a power failure (simulator operating mode), a power distribution unit, impedance measurement (tester operating mode) or water cooling (IP54).
Further options on request.

Energy efficiency: New technology, high efficiency,regenerative power supply

Scope of delivery:
Testsystem
Calibration protocol
Operation manual

EPS/TSDCR 06003000200 Bidirectional Testsystem Power feedback
Order code: 200500
Voltage:  5-300 VDC
Current:  +- 200 A
Input Power: 66 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 60 kW
Output Voltage: 5-300 V DC
Output Current: 0 to ±200 A
Dim.: 1400 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 06003000600 Bidirectional Testsystem Power feedback
Order code: 200501
Voltage:  5-300 VDC
Current:  +- 600 A
Input Power: 67 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 60 kW
Output Voltage: 5-300 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 06003001000 Bidirectional Testsystem Power feedback
Order code: 200502
Voltage:  5-300 VDC
Current:  +- 1000 A
Input Power: 68 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 60 kW
Output Voltage: 5-300 V DC
Output Current: 0 to ±1000 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 06006000600 Bidirectional Testsystem Power feedback
Order code: 200503
Voltage:  5-600 VDC
Current:  +- 600 A
Input Power: 67 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 60 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 1000 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10003000200 Bidirectional Testsystem Power feedback
Order code: 200505
Voltage:  5-300 VDC
Current:  +- 200 A
Power: 100000 W
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-300 V DC
Output Current: 0 to ±200 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10003000600 Bidirectional Testsystem Power feedback
Order code: 200506
Voltage:  5-300 VDC
Current:  +- 600 A
Input Power: 109 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-300 V DC
Output Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1000 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10003001000 Bidirectional Testsystem Power feedback
Order code: 200507
Voltage:  5-300 VDC
Current:  +- 1000 A
Input Power: 111 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-300 V DC
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10006000200 Bidirectional Testsystem Power feedback
Order code: 200508
Voltage:  5-600 VDC
Current:  +- 200 A
Input Power: 107 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±200 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10006000600 Bidirectional Testsystem Power feedback
Order code: 200509
Voltage:  5-600 VDC
Current:  +- 600 A
Input Power: 108 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±600 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10006001000 Bidirectional Testsystem Power feedback
Order code: 200510
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 111 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10008000200 Bidirectional Testsystem Power feedback
Order code: 200511
Voltage:  5-800 VDC
Current:  +- 200 A
Input Power: 107 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±200 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 10008000600 Bidirectional Testsystem Power feedback
Order code: 200512
Voltage:  5-800 VDC
Current:  +- 600 A
Input Power: 109 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 100 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±600 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095