Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Behavior



All products

E/PS 9080-100 1U Laboratory Power Supply
Order code: 200005
Voltage:  0-80 VDC
Current:  0-100 A
Power: 3000 W
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 100 A
Output Power: 0-3000 W
Input Voltage:207(180)-264VAC,1ph.+N,PE 50/60Hz
Pout max. 2500W: 180-207 VAC
Dimensions (WxHxD): 19"x1Ux500mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series- and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 9080-170-3U Laboratory Power Supply
Order code: 102582
Voltage:  0-80 VDC
Current:  0-170 A
Power: 0-5000 W
Design: 19 inch
Shipping time: quickly deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A -170 A
Output Power: 0-5000 W
Input Voltage: 340-460 VAC; 2ph 50/60 Hz
Dimensions (WxHxD): 19"x3Ux609mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO) Interface
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 9080-20 T Laboratory Power Supply
Order code: 200114
Voltage:  0-80 VDC
Current:  0-20 A
Power: 0-640 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 20 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9080-40 T Laboratory Power Supply
Order code: 200117
Voltage:  0-80 VDC
Current:  0-40 A
Power: 0-1000 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9080-50 1U Laboratory Power Supply
Order code: 200000
Voltage:  0-80 VDC
Current:  0-50 A
Power: 0-1500 W
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A -50 A
Output Power: 0-1500 W
Input Voltage:150-264VAC,1ph.+N,PE;50/60Hz
Pout max. 1000W: 100-150VAC
Dimensions (WxHxD): 19"x1Ux500mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series- and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 9080-60 T Laboratory Power Supply
Order code: 200121
Voltage:  0-80 VDC
Current:  0-60 A
Power: 1500W (1kW derating)
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 60 A
Output Power: 0-1500 W (1000 W Derating)
Input Voltage: 150-264 VAC (90-150 VAC Derating), 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 9200-04 T Laboratory Power Supply
Order code: 200112
Voltage:  0-200 VDC
Current:  0-4 A
Power: 0-320 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 4 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9200-10 T Laboratory Power Supply
Order code: 200115
Voltage:  0-200 VDC
Current:  0-10 A
Power: 0-640 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 10 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9200-15 T Laboratory Power Supply
Order code: 200118
Voltage:  0-200 VDC
Current:  0-15 A
Power: 0-1000 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 15 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9200-25 1U Laboratory Power Supply
Order code: 200001
Voltage:  0-200 VDC
Current:  0-25 A
Power: 0-1500 W
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 25 A
Output Power: 0-1500 W
Input Voltage:150(100)-264VAC,1ph.+N,PE;50/60Hz
Pout max. 1000W: 100-150VAC
Dimensions (WxHxD): 19"x1Ux500mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series- and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 9200-25 T Laboratory Power Supply
Order code: 200122
Voltage:  0-200 VDC
Current:  0-25 A
Power: 1500W (1kW derating)
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 25 A
Output Power: 0-1500 W (1000 W Derating)
Input Voltage: 150-264 VAC (90-150 VAC Derating), 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 9200-50 1U Laboratory Power Supply
Order code: 200006
Voltage:  0-200 VDC
Current:  0-50 A
Power: 3000 W
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 50 A
Output Power: 0-3000 W
Input Voltage:207(180)-264VAC,1ph.+N,PE;45/66Hz
Pout max. 2500W: 180-207 VAC
Dimensions (WxHxD): 19"x1Ux500mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series- and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200