Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design



Categories

E/PS 9000 T Laboratory Power Supply 320-1500 W

E/PS 9000 T Laboratory Power Supply 320-1500 W EPS's space-saving laboratory power supplies of series "E/PS 9000 T" are especially suitable for the use in test and development applications, in laboratories and research. Owing to a special filtering, the HF and NF output ripple are reduced to a level closing up to those of linear technology power supplies.

Different units with DC output voltages between 0-40V (SELV) and high 0-500V, currents between 0-4A and 0-60A and power from 0- 320/640/1000/1500W.

All models are microprocessor-controlled. This allows accurate and rapid measurement and display of actual values. Setpoints and actual values, status displays and messages are clearly displayed on an intuitive TFT touch panel. Models with a nominal voltage of 200V or higher include a discharge circuit for the output capacities. For no load or low situations, it ensures that the dangerous output voltage can sink to below 60V DC in max.10 seconds (SELV according to EN61010).
The implemented supervisions can help to reduce test equipment and make it almost unnecessary to install external supervision hardware and software.

For the integration into semi-automatic and remotely controlled test and automatic systems, the units offer a USB interface for standard.
The control software EPS/PC (124175) for Windows allows remote control of multiple similar or different devices (optional, up to 20). It has a clear display for all set and actual values, as well as direct input mode of SCPI and ModBus commands and a firmware update function.

Optionally available are an isolated Analog-/USB/Ethernet interface module, calibration protocol and extended warranty up to 5 years as well a UK wall socket adapter.

Energy efficiency: Auto-ranging, high efficiency, temperature controlled fans

Scope of delivery:
Power Supply Unit
Test report
Mains cord 1,5m
IEC plug (option UK or US plug)
USB cable 1,8m
USB-Stick with manual and Software

E/PS 9080-60 T Laboratory Power Supply
Order code: 200121
Voltage:  0-80 VDC
Current:  0-60 A
Power: 1500W (1kW derating)
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 60 A
Output Power: 0-1500 W (1000 W Derating)
Input Voltage: 150-264 VAC (90-150 VAC Derating), 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 9200-25 T Laboratory Power Supply
Order code: 200122
Voltage:  0-200 VDC
Current:  0-25 A
Power: 1500W (1kW derating)
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 25 A
Output Power: 0-1500 W (1000 W Derating)
Input Voltage: 150-264 VAC (90-150 VAC Derating), 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 9500-10 T Laboratory Power Supply
Order code: 200123
Voltage:  0-500 VDC
Current:  0-10 A
Power: 1500W (1kW derating)
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 500 VDC
Output Current: 0 A - 10 A
Output Power: 0-1500 W (1000 W Derating)
Input Voltage: 150-264 VAC (90-150 VAC Derating), 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 9040-20 T Laboratory Power Supply
Order code: 200110
Voltage:  0-40 VDC
Current:  0-20 A
Power: 0-320 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 20 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9080-10 T Laboratory Power Supply
Order code: 200111
Voltage:  0-80 VDC
Current:  0-10 A
Power: 0-320 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 10 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9200-04 T Laboratory Power Supply
Order code: 200112
Voltage:  0-200 VDC
Current:  0-4 A
Power: 0-320 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 4 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9040-40 T 640 W Laboratory Power Supply
Order code: 200113
Voltage:  0-40 VDC
Current:  0-40 A
Power: 0-640 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 40 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9080-20 T Laboratory Power Supply
Order code: 200114
Voltage:  0-80 VDC
Current:  0-20 A
Power: 0-640 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 20 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9200-10 T Laboratory Power Supply
Order code: 200115
Voltage:  0-200 VDC
Current:  0-10 A
Power: 0-640 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 10 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x352mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9040-40 T 1000 W Laboratory Power Supply
Order code: 200116
Voltage:  0-40 VDC
Current:  0-40 A
Power: 0-1000 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9080-40 T Laboratory Power Supply
Order code: 200117
Voltage:  0-80 VDC
Current:  0-40 A
Power: 0-1000 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121


E/PS 9200-15 T Laboratory Power Supply
Order code: 200118
Voltage:  0-200 VDC
Current:  0-15 A
Power: 0-1000 W
Design: Tower
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 15 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 92x237x412mm
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software

Country of origin: Germany
Customs tariff code: 8504.3121