EPS/TSDCR Regenerative DC Load System 60kW-1,3MW

EPS/TSDCR Regenerative DC Load System 60kW-1,3MW Source - Sink - Battery Charger/Tester/Simulator - Inverter - up to 650kW/kVA from EPS Stromversorgung

The coordinated test systems EPS/TSDCR from EPS Stromversorgung are suitable for tests during development, i.e. tests of electrical drives as well as fuel cells and their corresponding components such as inverters, batteries (discharging and charging) and switches suitable. The outputs go up to 1,3MW in a voltage range from 5 to 1500V and a current range up to 1000A (4000A).

The special feature of these systems is that the electrical energy absorbed in generator operation is fed back into the power supply grid with high efficiency. External loads (resistors) are thus superfluous and electrical energy that would otherwise be "burned" can be profitably recycled. This regenerative capability is a decisive factor in most test applications, as they work with unusually high powers.
To increase performance, either parallel connection (up to 2000A) or a multi-channel system (up to 4000A) is possible. In contrast to conventional DC sources, the multi-channel system has two or four independently usable output channels and can work both as a source and as a sink.

All systems have an isolated output and a TFT touch panel for entering or displaying values and alarms.

They can also be controlled via CAN, MOD-Bus, SCPI / TCP-IP, VNC and optionally via RS232 / USB, HighSpeed /Analog, HighSpeed CAN, Profibus, Profinet and Ethercat.

The test system can be freely programmed and has specific algorithms that enable a wide variety of tests such as battery tests, testing of fuel cells and solar systems (inverter option), DC electric motors, super capacitors and reactive power compensation.

Comprehensive protective measures, such as an event memory integrated as standard and a safety controller (level "d") completes the concept.

The system can be "upgraded" customer-specifically, e.g. with insulation monitoring, an additional, protective diode for safe sink operation, DC contactors for disconnection under load, a power distribution unit, energy meter or water cooling (IP54).
The systems are CE certified and can optionally be adapted according to UL.
Further options on request, as well as higher voltages and currents.

Energy efficiency: New technology, high efficiency regenerative power supply with over 93%

Scope of delivery:
Testsystem
Calibration protocol
Operation manual


EPS/TSDCR 25006001000 Regenerative DC Load System
Order code: 300028
Input Power: 250 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 250 kW
Voltage: 5-600 V DC
Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25008000600 Regenerative DC Load System
Order code: 300029
Input Power: 250 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 250 kW
Voltage: 5-800 V DC
Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25008001000 Regenerative DC Load System
Order code: 300030
Input Power: 250 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 250 kW
Voltage: 5-800 V DC
Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25010000600 Regenerative DC Load System
Order code: 300031
Input Power: 250 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 250 kW
Voltage: 5-1000 V DC
Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25010001000 Regenerative DC Load System
Order code: 300032
Input Power: 250 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 250 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 30015001000 Regenerative DC Load System
Order code: 300033
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 300 kW
Output Voltage: 10-1500 V DC (2x 5-750V DC)
Voltage at the centre
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2200 h mm
and 1200 d x 800 d x 2200 h mm
incl. 200 mm socket and cooling unit
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: separate cooling circuit with
water/water heat exchanger
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32003001000 Regenerative DC Load System
Order code: 300035
Input Power: 320 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 320 kW
Voltage: 5-600 V DC
Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32008000600 Regenerative DC Load System
Order code: 300036
Input Power: 320 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 320 kW
Voltage: 5-800 V DC
Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32008001000 Regenerative DC Load System
Order code: 300037
Input Power: 320 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 320 kW
Voltage: 5-800 V DC
Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32010000600 Regenerative DC Load System
Order code: 300038
Input Power: 320 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 320 kW
Voltage: 5-1000 V DC
Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32010001000 Regenerative DC Load System
Order code: 300039
Input Power: 320 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 320 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32012000600 Regenerative DC Load System
Order code: 300040
Current:  +- 600 A
Input Power: 342 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 10-1200 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095