Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Behavior



All products

E/PS 10060-1000 4U Laboratory Power Supply
Order code: 200904
Voltage:  0-60 VDC
Current:  0-1000 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 60 VDC
Output Current: 0 A - 1000 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10060-120 2U Laboratory Power Supply
Order code: 200039
Voltage:  0-60 VDC
Current:  0-120 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 60 VDC
Output Current: 0 A -120 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10060-170 3U Laboratory Power Supply
Order code: 200870
Voltage:  0-60 VDC
Current:  0-170 A
Power: 0-5000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 60 VDC
Output Current: 0 A -170 A
Output Power: 0-5000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 3 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10060-340 3U Laboratory Power Supply
Order code: 200881
Voltage:  0-60 VDC
Current:  0-340 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 60 VDC
Output Current: 0 A - 340 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10060-510 3U Laboratory Power Supply
Order code: 200892
Voltage:  0-60 VDC
Current:  0-510 A
Power: 15kW/ 9kW derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 60 VDC
Output Current: 0 A - 510 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10060-60 2U Laboratory Power Supply
Order code: 200029
Voltage:  0-60 VDC
Current:  0-60 A
Power: 1500W/1200W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 60 VDC
Output Current: 0 A -60 A
Output Power: 0-1500 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1200 W, 45...66 Hz
Pout max. 1000W: 90-150VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10080-1000 4U Laboratory Power Supply
Order code: 200905
Voltage:  0-80 VDC
Current:  0-1000 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 1000 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10080-120 2U Laboratory Power Supply
Order code: 200040
Voltage:  0-80 VDC
Current:  0-120 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A -120 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10080-170 3U Laboratory Power Supply
Order code: 200871
Voltage:  0-80 VDC
Current:  0-170 A
Power: 5kW/ 3kW derating
Design: 19 inch
Shipping time: quickly deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A -170 A
Output Power: 0-5000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 3 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10080-340 3U Laboratory Power Supply
Order code: 200882
Voltage:  0-80 VDC
Current:  0-340 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 340 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Low cost: E/PS 8080-340-3U (123272)

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10080-60 2U Laboratory Power Supply
Order code: 200030
Voltage:  0-80 VDC
Current:  0-60 A
Power: 1500W/1200W derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A -60 A
Output Power: 0-1500 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1200 W, 45...66 Hz
Pout max. 1000W: 90-150VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 10200-140 3U Laboratory Power Supply
Order code: 200883
Voltage:  0-200 VDC
Current:  0-140 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 140 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200