Filter
Categories
All products
E/PS 11000-10 2U Laboratory Power Supply
Order code: 200045
Voltage: 0-1000 VDC
Current: 0-10 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Voltage: 0-1000 VDC
Current: 0-10 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time:
Output Voltage: 0 VDC -1000 VDC
Output Current: 0 A -10 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A -10 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11000-30 3U Laboratory Power Supply
Order code: 200887
Voltage: 0-1000 VDC
Current: 0-30 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Voltage: 0-1000 VDC
Current: 0-30 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Shipping time:
Output Voltage: 0 VDC - 1000 VDC
Output Current: 0 A - 30 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 30 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11000-40 3U Laboratory Power Supply
Order code: 200898
Voltage: 0-1000 VDC
Current: 0-40 A
Power: 15kW/ 9kW derating
Design: 19 inch
Voltage: 0-1000 VDC
Current: 0-40 A
Power: 15kW/ 9kW derating
Design: 19 inch
Shipping time:
Output Voltage: 0 VDC - 1000 VDC
Output Current: 0 A - 40 A
Output Power: 0-15000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 40 A
Output Power: 0-15000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11000-80 4U Laboratory Power Supply
Order code: 200911
Voltage: 0-1000 VDC
Current: 0-80 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Voltage: 0-1000 VDC
Current: 0-80 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time:
Output Voltage: 0 VDC - 1000 VDC
Output Current: 0 A - 80 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 80 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11500-06 2U Laboratory Power Supply
Order code: 200046
Voltage: 0-1500 VDC
Current: 0-6 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Voltage: 0-1500 VDC
Current: 0-6 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time:
Output Voltage: 0 VDC -1500 VDC
Output Current: 0 A -6 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A -6 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11500-20 3U Laboratory Power Supply
Order code: 200888
Voltage: 0-1000 VDC
Current: 0-20 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Voltage: 0-1000 VDC
Current: 0-20 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Shipping time:
Output Voltage: 0 VDC - 1000 VDC
Output Current: 0 A - 20 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 20 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11500-30 3U Laboratory Power Supply
Order code: 200899
Voltage: 0-1500 VDC
Current: 0-30 A
Power: 15kW/ 9kW derating
Design: 19 inch
Voltage: 0-1500 VDC
Current: 0-30 A
Power: 15kW/ 9kW derating
Design: 19 inch
Shipping time:
Output Voltage: 0 VDC - 1500 VDC
Output Current: 0 A - 30 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 30 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 11500-60 4U Laboratory Power Supply
Order code: 200912
Voltage: 0-1500 VDC
Current: 0-60 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Voltage: 0-1500 VDC
Current: 0-60 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time:
Output Voltage: 0 VDC - 1500 VDC
Output Current: 0 A - 60 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 60 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 12000-20 3U Laboratory Power Supply
Order code: 200900
Voltage: 0-2000 VDC
Current: 0-20 A
Power: 0-15000 W
Design: 19 inch
Voltage: 0-2000 VDC
Current: 0-20 A
Power: 0-15000 W
Design: 19 inch
Shipping time:
Output Voltage: 0 VDC - 2000 VDC
Output Current: 0 A - 20 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 20 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 12000-40 4U Laboratory Power Supply
Order code: 200913
Voltage: 0-2000 VDC
Current: 0-40 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Voltage: 0-2000 VDC
Current: 0-40 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time:
Output Voltage: 0 VDC - 2000 VDC
Output Current: 0 A - 40 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 40 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks
Country of origin: Germany
Customs tariff code: 8504.3200
E/PS 2042-06B Laboratory Power Supply
Order code: 200410
Voltage: 0-42 VDC
Current: 0-6 A
Power: 100 W
Design: Desktop
Voltage: 0-42 VDC
Current: 0-6 A
Power: 100 W
Design: Desktop
Shipping time:
Input Voltage: 90 V bis 264 VAC 45/65 Hz
Output Voltage: 0 V - 42 VDC
Output Current: 0 A - 6 A
Output Power: 100 W
Dimensions (WxHxD mm): 174 x 82 x 240
Colored TFT display
USB Interface with software, incl. LabView VIs
OVP, OCP, OTP
Constant Voltage (CV), Current (CC)
Preset of Voltage and Current
Country of origin: China
Customs tariff code: 8504.3121
Output Voltage: 0 V - 42 VDC
Output Current: 0 A - 6 A
Output Power: 100 W
Dimensions (WxHxD mm): 174 x 82 x 240
Colored TFT display
USB Interface with software, incl. LabView VIs
OVP, OCP, OTP
Constant Voltage (CV), Current (CC)
Preset of Voltage and Current
Country of origin: China
Customs tariff code: 8504.3121
E/PS 2042-10B Laboratory Power Supply
Order code: 200411
Voltage: 0-42 VDC
Current: 0-10 A
Power: 160 W
Design: Desktop
Voltage: 0-42 VDC
Current: 0-10 A
Power: 160 W
Design: Desktop
Shipping time:
Input Voltage: 90 V bis 264 VAC 45/65 Hz
Output Voltage: 0 V - 42 VDC
Output Current: 0 A - 10 A
Output Power: 160 W
Dimensions (WxHxD mm): 174 x 82 x 240
USB Interface with software, incl. LabView VIs
Colored TFT display
OVP, OCP, OTP
Constant Voltage (CV), Current (CC)
Preset of Voltage and Current
Country of origin: China
Customs tariff code: 8504.3121
Output Voltage: 0 V - 42 VDC
Output Current: 0 A - 10 A
Output Power: 160 W
Dimensions (WxHxD mm): 174 x 82 x 240
USB Interface with software, incl. LabView VIs
Colored TFT display
OVP, OCP, OTP
Constant Voltage (CV), Current (CC)
Preset of Voltage and Current
Country of origin: China
Customs tariff code: 8504.3121