Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Behavior



All products

E/PS 10200-210 3U Laboratory Power Supply
Order code: 200894
Voltage:  0-200 VDC
Current:  0-210 A
Power: 15kW/ 9kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 210 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10200-25 2U Laboratory Power Supply
Order code: 200031
Voltage:  0-200 VDC
Current:  0-25 A
Power: 1500W/1200W derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A -25 A
Output Power: 0-1500 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1200 W, 45...66 Hz
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10200-420 4U Laboratory Power Supply
Order code: 200906
Voltage:  0-200 VDC
Current:  0-420 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 420 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10200-50 2U Laboratory Power Supply
Order code: 200041
Voltage:  0-200 VDC
Current:  0-50 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: quickly deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A -50 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10200-70 3U Laboratory Power Supply
Order code: 200872
Voltage:  0-200 VDC
Current:  0-70 A
Power: 5kW/ 3kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 200 VDC
Output Current: 0 A - 70 A
Output Power: 0-5000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 3 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Series and Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200


E/PS 10360-120 3U Laboratory Power Supply
Order code: 200895
Voltage:  0-360 VDC
Current:  0-120 A
Power: 15kW/ 9kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 360 VDC
Output Current: 0 A - 120 A
Output Power: 0-15000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 9 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10360-15 2U Laboratory Power Supply
Order code: 200032
Voltage:  0-360 VDC
Current:  0-16 A
Power: 1500W/1200W derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 360 VDC
Output Current: 0 A -15 A
Output Power: 0-1500 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1200 W, 45...66 Hz
Pout max. 1000W: 90-150VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10360-240 4U Laboratory Power Supply
Order code: 200907
Voltage:  0-360 VDC
Current:  0-240 A
Power: 0-30000 W
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 360 VDC
Output Current: 0 A - 240 A
Output Power: 0-30000 W
Input Voltage: 380V/400V/480V AC +-10% 3ph.,
208V derating to 18 kW, 45...66 Hz
Dimensions (WxHxD): 19"x4Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10360-30 2U Laboratory Power Supply
Order code: 200042
Voltage:  0-360 VDC
Current:  0-30 A
Power: 3000W/1500W derating
Design: 19 inch
Behavior: Unidirectional
Shipping time: deliverable
Output Voltage: 0 VDC - 360 VDC
Output Current: 0 A -30 A
Output Power: 0-3000 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1500 W, 45...66 Hz
Pout max. 2500W: 180-207VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10360-40 3U Laboratory Power Supply
Order code: 200873
Voltage:  0-360 VDC
Current:  0-40 A
Power: 5kW/ 3kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 360 VDC
Output Current: 0 A - 40 A
Output Power: 0-5000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 3 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10360-80 3U Laboratory Power Supply
Order code: 200884
Voltage:  0-360 VDC
Current:  0-80 A
Power: 10 kW/ 6kW derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 360 VDC
Output Current: 0 A - 80 A
Output Power: 0-10000 W
Input Voltage:380V/400V/480V AC +-10% 3ph.,
208V derating to 6 kW, 45...66 Hz
Dimensions (WxHxD): 19"x3Ux668mm
Supervision, OVL, UVL
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog (ISO)/USB/LAN Interface with LabView VIs
Extra USB-Port for USB-Sticks

Country of origin: Germany
Customs tariff code: 8504.3200

E/PS 10500-10 2U Laboratory Power Supply
Order code: 200033
Voltage:  0-500 VDC
Current:  0-10 A
Power: 1500W/1200W derating
Design: 19 inch
Shipping time: deliverable
Output Voltage: 0 VDC - 500 VDC
Output Current: 0 A -10 A
Output Power: 0-1500 W
Input Voltage: 208/220V/230V/240V AC +-10% 1ph.,
110V/120V derating to 1200 W, 45...66 Hz
Pout max. 1000W: 90-150VAC
Dimensions (WxHxD): 19"x2Ux462mm
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
Analog Interface, isolated
Ethernet and USB Interface with LabView VIs

Country of origin: Germany
Customs tariff code: 8504.3200